BFT II Analyzer
High-performance analyzer for the low-volume lab.
The BFT II Analyzer combines the advantages of mechanical and photo-optical clot-detecting principles by employing a unique turbodensitometric detection device. The semi-automated, dual-channel coagulometer is ideal for low-volume laboratories performing routine coagulation tests.
- Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
- Pre-defined assays with stored reference curves
- Automatic calculation of PT in sec, % of norm, INR, Fibrinogen in mg/dL or g/L
- Dual measuring channels allow for simultaneous determinations
- Half-volume and single cuvette testing require minimal sample volume
- Built-in thermal printer for consolidated result handling
The BFT II Analyzer is a dual-channel coagulometer designed for the lowest volume lab. It combines the advantages of mechanical and photo-optical clot detecting principles.
Total efficiency
- Stores reference curves
- Automatic result calculation, e.g., PT in sec, % of norm/ PR/ INR, Fibrinogen in mg/dL or g/L
- Temperature controlled incubation block for reagents and samples
- Sample mixing during measurement
Ease-of-use
- Light protection cap reduces the risk of user errors by keeping the pipetting channel closed unless a cuvette has been inserted
- Built-in timer for incubation
- Membrane keypad for easy handling of test processing
- Pre-programmed methods
Labor and cost savings
- Half-volume and single cuvette testing require minimal sample volume
- Memory function for reference curves
- As a back-up analyzer, the BFT II provides data comparable to those obtained with other Siemens hemostasis analyzers
PT Reagents
Dade Innovin sec
Dade Innovin %
Thromborel® S INR
Thromborel S sec
Thromborel S %
APTT Reagents
Dade Actin FS
Dade Actin FSL
Pathromtin® SL
Fibrinogen Reagents
Thrombin Time Reagents
Test Thrombin Reagent
Thromboclotin®
Factor Deficient Reagents
Factor II-Thromborel S
Factor V-Dade Innovin
Factor V-Thromborel S
Factor VII-Dade Innovin
Factor VII-Thromborel S
Factor VIII-Dade Actin
Factor VIII-Pathromtin SL
Factor IX-Dade Actin
Factor IX-Pathromtin SL
Factor X-Dade Innovin
Factor X-Thromborel S
Factor XI-Dade Actin
Factor XI-Pathromtin SL
Factor XII-Dade Actin
Factor XII-Pathromtin SL
Lupus Anticoagulant Reagents
LA 2 Confirmation Reagent
Thrombosis Risk Reagents
ProC Global FV
Protein C
Dimensions
Approx. 200 mm x 300 mm x 100 mm (W x D x H)
Weight
Approx. 3.8 kg
Onboard Capacity
4 reagents including 1 reagent mixer
Incubation block for up to 30 cuvettes
Throughput
Approx. 60 PT tests/hour
Approx. 30 APTT tests/hour
Sample Handling
Manual sample pipetting
Reagent Handling
Manual reagent pipetting
4 positions GW 15 – bottles
GW5 bottles using reducer rings
Operation
Pre-programmed methods
2 free positions for user-defined methods
Built-in timer
Automatic timer start and stop
Why Choose Us
We believe that success is achieved with professionalism, integrity and perfect teamwork, built on the high moral values of our employees.
Our policy is based on impeccable planning, control and execution, through which we achieve maximum satisfaction of our customers.
Professional
customer service
A wide range of laboratory analyzers
Trained and experienced specialists
Certificate
ISO 13485:2012